HORIZONTAL VENT/INTAKE TERMINATIONS
12" Min.
Vent
24" Max.
3" Min.
12" Min.
Screen
24" Max.
Air
Intake
90°
Medium
Radius
Elbow
Figure 6
Horizontal Vent Termination
Position the combustion air intake terminal away from
obstructions, above anticipated snow accumulations, and
at least 12 inches above grade, as shown in Figure 6.
The exhaust vent must penetrate the wall within the
shaded region as shown in Figure 6.
All exhaust vent and air intake terminal fittings must be
medium radius (1/4 bend DWV) 90 degree elbows.
To prevent unnecessary shutdown of furnace due to
pressure switch trips, always determine anticipated snow
accumulation level, and install the terminals accordingly to
prevent exhaust vent and air intake blockages.
If installation above snow accumulation is required, add
additional elbows as shown in Figure 7. A 12 inch minimum
clearance between the air intake and the highest antici-
pated snow level must be maintained. The exhaust vent
must penetrate the wall within the shaded region as shown
in Figure 7.
Air Intake
Screen
90°
Medium Radius
Elbow
Vent
12" Min.
24" Max.
12" Min.
24" Max.
3" Min.
12" Min. Above
Highetst Anticipated
Snow Level
Figure 7
Horizontal Vent Termination Above
Anticipated Snow Level
thick closed cell foam insulation such as Armaflex or
Insultube.
LOCATION OF EXHAUST AND INTAKE
TERMINATIONS
This furnace can be installed with either a vertical or
horizontal direct vent. In either case, the exhaust vent and
the combustion air intake pipe must be located on the
same side of the structure and separated by no less than
3 inches and no more than 24 inches.
This ensures enough distance to prevent flue gas recircu-
lation and limits the distance to ensure the vent outlet and
air inlet terminals are in the same atmospheric pressure
zone.
The following points must also be considered when install-
ing the vent pipe in either a horizontal or vertical applica-
tion:
1. The vent termination must be at least 3 feet above any
forced air inlet located within 10 feet.
Exception: This provision shall not apply to the com-
bustion air intake of a direct vent furnace.
2. The vent termination must be at least 12 inches from
any door, window, or gravity air inlet into any building.
3. The vent must terminate at least 2 feet above ground
level or roof level. If heavy snow accumulation is
expected, this distance will need to be increased.
4. The vent shall not terminate over public walkways or
over an area where condensate or vapor could create
a nuisance or hazard or could be detrimental to the
operation of regulators, relief valves, or other equip-
ment.
5. In addition, the combustion air intake should not be
terminated in areas that are frequently very dusty or
dirty.
CAUTION
Do not terminate the combustion air intake
where the air is often heavily contaminated
with compounds containing chlorine or
fluorine. Common residential sources of
such compounds include:
Swimming pools and swimming pool
pumps/filter
Clothes dryer vents
Remote air conditioning or heat pump
units (A refrigerant leak would
contaminate the combustion air.)
Plumbing vent stacks
Bathroom or swimming pool exhaust fans
Undried paint strippers, adhesives,
paints, varnishes, sealers, waxes, and
solvents. These are often used during
new construction or remodeling.
Various commercial and industrial
processes may also be sources of chlorine/
fluorine compounds.