C/D - 7
ACCESSORIES
CDP302 230/208V
CDP402 265V
Condensate Drain Kit
Attaches to the wall sleeve base pan for controlled inter-
nal or external disposal of condensate
Security Key Locks
In conjunction with the tamper-resistant front, the installa-
tion of Amana’s security key locks prevents tampering of the
controls used to set temperature, heating and cooling
functions. U.L. approved for institutional use only.
Remote Escutcheon Kit (not shown)
Optional kit for use with units controlled via a wall thermo-
stat. Replaces knob controls for units operated by wall
thermostat.
Condenser Baffle Kit
For use on non-baffled grilles. These deflectors direct the
air in toward the center and away from the inlet to prevent
recirculation of the hot condenser air.
Duct Extension Kit
Extends air distribution to an adjoining room. Consists of a
main duct for the room of origin and an extension duct to
reach the adjoining room and terminal duct.
Power Vent Kit (not shown)
Installation of Power Vent increases CFM up to approxi-
mately 95. Vent door will automatically close when unit fan
is off.
Power Door Kit (not shown)
Vent door will automatically open when unit fan is on.
Hydronic Transformer Relay Kit (not shown)
Add-on kit that allows field conversion of a standard PTC
unit to a Hydronic unit.
Hydronic Heat Kit
Add-on kits fit all units allowing the addition of hydronic
water or hydronic steam heat to cooling and heating units.
The kits feature left- or right-hand piping. Unit retains com-
plete service access with a kit installed.
Hydronic Valves (not shown)
Water and steam valves are available for use with the
HWK03 (water) and HVK03 (steam) heat kits. (See Ar-
chitects and Engineers Manual for specifications.)
Condensate Removal Pump (not shown)
Can be field installed. Assists in removing condensate
developed by heat pump operation and transfers it to in-
door coil to dissipate into room while adding humidity to the
room.
Spare Filters (not shown)
Helps keep dirt and lint out of the air and off the coil, thus
increasing units efficiency. Amana® brand filters are
easy to remove, wash and replace.
NEW! Replacement Charcoal Filter Kit
(not shown)
Absorbs odors caused by cigarette, pipe or cigar smoke
& odors caused by mold, mildew, etc. Filters are made of
polyester fibers coated with activated charcoal and are
individually wrapped. This filters are permanent and can
be washed or cleaned. Call your Amana
®
brand sales
person for details. 10 filters per pack.
MDK02 Main Duct
EDK02 Extension Duct
TDK02 Terminal Duct
Hydronic Air
Inlet
FRONT VIEW
8-1/4"
20-3/16"
2-1/8"
53"
Steam/Water
Coil Position
Hot Water Inlet / Outlet Connections
Steam Inlet / Outlet Connection
Hot Water Inlet / Outlet Connections
Steam Inlet / Outlet Connections
16-3/4"
(unit wi/Hronic Kit installed)
FK10A Filters (10/pack)
KL03 Security Key Lock
DGK1
Condenser
Baffle Kit
HWK03 Hydronic Water Kit
HVK03 Hydronic Steam Kit
HTK3 230/208V
HTK4 265V
PVK3A 230/208V
PVK4A 265V
PDK3A 230/208V
PDK4A 265V
Condenser
Condenser Baffles
DK9001
Condensate
Drain Kit
Gasket
Cover
Plate
1/2" OD
Drain Fitting
(12.7mm)
*Poptop Actuator
BRACKET
TRANSITION
DUCT
MAIN DUCT
MINIMUM
5"
BOTH SIDES
42-27/32"
6" TO 42-1/2"
BRACKET
5"
PARTITION
WALL
DUCT EXTENSION
AIR FLOW
DUCT
TERMINATION
KIT
AIR FLOW
1" to
adjoining
wall
surface
EDK02
MDK02
(Included in
MDK02)
Model
Nominal
BTUs
230V 208V 265V
Rated Watts
All 1,500 1,200 1,500
7K & 9K 6.9 6.2 6.1
12K & 15K 7.1 6.4 6.3
7K & 9K 8.6 8.6 7.5
12K & 15K 8.8 8.8 7.7
Fuse Size
All 15 15 15
Minimum
Ampacity
Full Load Amps
(including fan)
HK315F 230/208V
HK415F 265V
VS2WNCA* 2 way-24V-Steam-End Switch
VS2WNOA* 2 Way-24V-NO-Steam-End Switch
VW2WNCA* 2 Way-24V-NC-End Switch
VW3WNC2B* 3 Way-24V-NC/NO-End Switch
AMANA C/D MODELS
AMANA C/D MODELS
Heater Kit
(for heaterless units only) (not shown)
Optional 1.5kW heater kits are available for use
only with models originally shipped without elec-
tric heat. Ask salesperson for details.
NEW!
CFK10A Charcoal Filter Kit
10/Pack
REK10B
Remote Escutcheon
Kit (10/pack)
Each kit contains 80 wires and wire
nuts, enough to attach a thermostat and
one additional accessory to ten PTAC
units. Wires are assorted colors for
easy attachment.