4
Routine Maintenance
Replacing or Cleaning Filter
IMPORTANT NOTE: Never operate unit without a filter
installed as dust and lint will build up on internal parts
resulting in loss of efficiency, equipment damage and
possible fire.
A return air filter is not supplied with this unit; however,
there must be a means of filtering the return air. The
filter(s) may be located in the return air duct(s). Consult
with your installing dealer for the actual location of the
return air filter(s) in your unit.
See Specification Sheet for filter sizes.
A dirty filter is the most common cause of inadequate
heating or cooling performance. Filter inspection should
be made at least every two months; more often if neces-
sary because of local conditions and usage.
Dirty throwaway filters should be discarded and replaced
with a new, clean filter. Dirty permanent filters should be
washed with water, thoroughly dried and sprayed with a
filter adhesive before being reinstalled. (Filter adhesives
may be found at many hardware stores.) Permanent
filters should last several years. However, should one
become uncleanable, it should be replaced.
When installing a new filter or reinstalling an old one,
always make certain the air flow arrows on the filter point
in the proper direction.
Clean Outside Coil (Qualified Servicer Only)
Any Questions?
Most of your questions can be answered by your local Amana dealer. Check with your dealer first if you need any
further information regarding the operation, maintenance, or service of your unit. Then, if you should have any matters
which are not resolved locally, or if you would like information on other heating and cooling products or kitchen appli-
ances offered by Amana - please call us:
CONSUMER INFORMATION LINE
Amana Toll-Free
1-800-843-0304
(Not a technical assistance line for dealers.)
Extended Service Plan
Ask your participating Amana dealer about Amana’s extended service plan. It adds to the strong warranty with addi-
tional parts and labor coverage.
WARNING
To avoid death or personal injury due to electrical
shock, disconnect the electrical power before
cleaning the coil(s).
The coil with the outside air flowing over it should be
inspected annually and cleaned as frequently as neces-
sary to keep the finned areas free of lint, hair and debris.
Indoor Air Circulating Blower Motor
Lubrication
The air circulating blower motor bearings are perma-
nently lubricated and do not require additional oiling.
Outdoor Coil Fan Motor Lubrication
The fan motor is permanently lubricated and does not
require additional oiling.
Compressor
The compressor motor is hermetically sealed and does
not require additional oiling.