SS-DPTAC www.amana-ptac.com 13
SPECIFICATION SHEET
NEW INSTALLATIONS TYPICALLY REQUIRE A MINIMUM OF WS900D WALL SLEEVE
AND AN OUTDOOR GRILLE.
Wall Sleeves (WS900D)
The wall sleeve must be industry-accepted dimensions:
14⅛” depth x 42” width x 16
1
/16” height and con struct ed
of G90 HDG galvanized steel with a baked corrosion-
inhibiting urethane primer and baked-polyester topcoat
enamel. Sleeve must be insulated and shipped with a
weather resistant rear closure panel installed.
Outdoor Grilles
Outdoor grille must be architecturally extruded,
louvered aluminum (AGK01*B), one-piece polymer-
blend injection molded louver (PGK01*B) or standard
stamped aluminum (SGK**B). All other grilles must be
submitted to the PTAC manufacturer for feasibility,
airflow characteristics and compliance with UL
regulations, where necessary.
THE OPTIONAL ACCESSORIES LISTED BELOW PERFORM SPECIFIC FUNCTIONS REQUIRED
IN SOME INSTALLATIONS.
Condensate Drain Kit (DK900D)
Attaches to the bottom of the wall sleeve for di rec tion al-
con trolled internal or external dis pos al of condensate,
defrost or rain water.
Sub-base Kit (PTSB***E)
Necessary for UL listing requirements for 265V units
(Hard Wire Kit may be substituted for Sub-base kit).
Op tion al for 230/208V units. Must be pre-wired to
facilitate fi eld-electrical con nec tions and include a
NEMA 6 or 7 con fi g u ra tion electrical re cep ta cle. It must
have 2 leveling screws for sleeve support and ac cu rate
unit lev el ing during installation. Lo ca tions for fi eld
in stal la tion of physical disconnect switches, cartridge-
style fuse hold ers and circuit break ers must be pro vid ed.
Side-skirts must be provided with sub-bases. (PTSB000E
Non-Elec tri cal Sub-base available.)
Power Vent & Damper
Must be provided to maximize ventilation air intake to
up to approximately 95 CFM. Power vent must be off and
damper door closed when unit fan is de-energized.
Fuse Holder (included in 265V chassis)
Must be installed either in the unit or the sub-base
and must match the electrical re quire ments of the
chas sis.
Security Key Locks (KL03B)
Must be installed to prevent tampering of the unit
con trols. Unit room cabinet must also be secured to
the chassis with fi eld supplied screws. UL-ap proved for
institutional use only.
Disconnect Switch
Power disconnect switch must be installed in sub-base
for use as a physical disconnect, where required by
local codes.
Duct Kits (MDK02B, EDK02B, TDK02)
Three kits must be supplied to provide ducted,
con di tioned air into a second room: a main duct kit, an
ex ten sion duct kit and a terminal duct kit.
Hydronic Heat Kit
Is required for heating functions instead of elec tric
re sis tance heaters. Unit must retain complete service
access with the kit installed. Proper water or steam
valves must be used.
Condensate Removal Pump (Heat Pumps only)
Must be installed to assist in removing the condensate
de vel oped by the heat pump operation and transfer it
to the indoor coil to dissipate into the room, adding
hu mid i ty to the room.
Circuit Breaker Kit
Must be installed in sub-base to provide overcurrent
pro tec tion for proper 230/208V amperage. Can also be
used as a physical disconnect where local codes permit
for 230/208 voltage.
Hard Wire Kit
Must be used to permanently wire chassis for hard
wire purposes. (For 265V units, Hard Wire Kit may be
sub sti
tut ed with Sub-base Kit.)
Charcoal Filter Kit -- Optional (CFK10B)
Amana
®
brand Activated Charcoal fi lters absorb odors
caused by cigarette, pipe or cigar smoke and airborne
odors caused by mold, mildew, etc. These replacement
fi lters are polyester fi bers coated with activated
charcoal. Each fi lter is in di vid u al ly wrapped to assure
maximum ab sorp tion and durability when installed. (10
fi lters per kit.)
Thermostats
A manufacturer-approved manual, auto changeover or
pro gram ma ble traditional-wired ther mo stat must be
in stalled to pro vide full remote op er a tion of the chassis.
A Remote Es cutch eon Kit must be used to indicate
remote operation.