CUS®Copyright ©2009-2010 Goodman Manufacturing Company, L.P.RT6622012 Rev. 1April 2010This manual is to be used by qualified, professionally trained
10PRODUCT DESIGNPart Num ber 10123529O p e n S e ttin g (°F) 300AM VC80704BX**GMVC80704BX**2AM VC80905CX**GMVC80905CX**2AM VC81155CX**GMVC81155CX**
11PRODUCT DESIGNCoil Matches:A large array of Amana® brand coils are available for use with the ADVC8 furnaces, in downflow applications, and withAMVC
12PRODUCT DESIGNThermostats:ComfortNet™ CTK01A* Thermostat KitFilters:Filters are required with this furnace and must be provided by the installer. Th
13PRODUCT DESIGNDownflow Filters"A"MinReturn AirOptionalAccessDoorReturn air filters may be installated at the at the downflow top return.
FURNACE SPECIFICATIONS1. These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operatio
FURNACE SPECIFICATIONS151. These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operat
FURNACE SPECIFICATIONS1. These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operatio
BLOWER PERFORMANCE SPECIFICATIONS171. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heating spee
BLOWER PERFORMANCE SPECIFICATIONS181. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heating spee
BLOWER PERFORMANCE SPECIFICATIONS191. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heating spee
PRODUCT IDENTIFICATION2The model and manufacturing number are used for positive identification of component parts used in manufacturing.Please use the
BLOWER PERFORMANCE SPECIFICATIONS201. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heating spee
BLOWER PERFORMANCE SPECIFICATIONS211. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heating spee
BLOWER PERFORMANCE SPECIFICATIONS221. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heating spee
BLOWER PERFORMANCE SPECIFICATIONS231. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heating spee
BLOWER PERFORMANCE SPECIFICATIONS241. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heating spee
PERFORMANCE2530 40 50 60 70 80 90 110 120100130 140 150100908070605040302010OUTPUT BTU/HR x 1000BTU OUTPUT vs TEMPERATURE RISE CHARTTEMPERATURE RISE60
HIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY
HIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY
HIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY
HIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY
3PRODUCT IDENTIFICATIONThe model and manufacturing number are used for positive identification of component parts used in manufacturing. Pleaseuse th
4PRODUCT DESIGNNotes:1. Category I Venting is venting at a non-positive pressure.A furnace vented as Category I is considered a fan-as-sisted applianc
5PRODUCT DESIGNAlcove IllustrationREARSIDESIDEALCOVE24" at front is required for servicing or cleaning.Note: In all cases accessibility clearanc
COMPONENT IDENTIFICATION6躀Pressure SwitchTubular Heat ExchangerFlue Pipe ConnectionGas Line Entrance(Alternate)Induced Draft BlowerGas LineEntranceGas
7COMPONENT IDENTIFICATIONFlue Pipe ConnectionInduced Draft BlowerGas LineEntranceGas ValveRollout LimitJunction BoxWiring HarnessGrommetGas ManifoldIn
PRODUCT DIMENSIONS8AMVC8/GMVC8_____X*Alt. Gas InletHigh Voltage InletLow VoltageAlt. Gas InletAlt. High VoltageAlt. LowVoltageMODELS A BAMVC80704BX**G
9PRODUCT DIMENSIONS33-3/8”AB28”High VoltageElectricalLow VoltageElectricalGas InletMODEL A BNON-COMBUSTIBLEFLOOR BASEADVC80703BX** 17 1/2 16 SBT17ADVC